2.3.3.3.165. NXopt_window¶
Status:
base class, extends NXaperture
Description:
Symbols:
No symbol table
Structure:
ENTRY: (optional) NXentry
window_effects_corrected: (optional) NX_BOOLEAN
Was a window correction performed? If 'True' describe the window ...
Was a window correction performed? If ‘True’ describe the window correction procedure in ‘window_correction/procedure’.
window_effects_type: (optional) NX_CHAR
Type of effects due to this window on the measurement. ...
Type of effects due to this window on the measurement.
Any of these values:
interference effects
light absorption
light scattering
other
material: (optional) NX_CHAR
The material of the window. ...
The material of the window.
Any of these values:
quartz
diamond
calcium fluoride
zinc selenide
thallium bromoiodide
alkali halide compound
Mylar
other
material_other: (optional) NX_CHAR
If you specified ‘other’ as material, decsribe here what it is.
thickness: (optional) NX_FLOAT {units=NX_LENGTH}
Thickness of the window.
orientation_angle: (optional) NX_FLOAT {units=NX_ANGLE}
Angle of the window normal (outer) vs. the substrate normal ...
Angle of the window normal (outer) vs. the substrate normal (similar to the angle of incidence).
window_correction: (optional) NXprocess ⤆
Was a window correction performed? If 'True' describe the ...
Was a window correction performed? If ‘True’ describe the window correction procedure in ‘’
procedure: (optional) NX_CHAR
Describe when (before or after the main measurement + time ...
Describe when (before or after the main measurement + time stamp in ‘date’) and how the window effects have been corrected, i.e. either mathematically or by performing a reference measurement. In the latter case, provide the link to to the reference data in ‘reference_data_link’.
reference_data_link: (optional) NX_CHAR
Link to the NeXus file which describes the reference data if a ...
Link to the NeXus file which describes the reference data if a reference measurement for window correction was performed. Ideally, the reference measurement was performed on a reference sample and on the same sample, and using the same conditions as for the actual measurement with and without windows. It should have been conducted as close in time to the actual measurement as possible.